Tube heat exchanger Argon cooling

During the spring we have delivered a tube heat exchanger for gas cooling to an industrial client in the city of Luleå. It has now been installed and pressure tested and will be taken into operation shortly. The media on the tube side is Argon and 40% glycol/water mix on the shell side. The heat exchanger is in 1 pass configuration with a cooling effect of 45 kW. The unit is 2,4 meter long and 0,3 m in diameter with a heat transfer area of 25 m². With its titanium stabalized stainless steel material it ways in at 490 kg. If you
Back to Top